Careers Events Notices
 
Ecosafe - Safety Cabinet


Flammable Cabinets
(EN 14470-1)
Flammable Cabinets
Corrosive Cabinets
Toxic Cabinets and Multirisk
Pesticide Range
Fume Hoods and Cabinets
Retention and Shelvings

Cans and Anti-Fire Equipments


Showers and First-Aid Equipments
Exhausting Systems
 
 
Download Catalo
 

Safety Showers, Eye-Washers and First-Aid Equipments

Home  »  Products  »  Ecosafe - Safety Cabinet  »  Showers and First-Aid Equipments

SUMMARY

Safety Eye - Washers

 

Safety Showers

 

Safety Combination Unit

 

Self - Contained Shower and Eye - Washers

 

Medicine Cabinet

 

MAIN INFORMATIONS

For security reasons, safety showers and eye-washers are highly recommended in every working area where chemical projections danger exist. Thus, they can be found in:

  • Chemical and pharmaceutical industries,
  • Food-processing and automobile industries,
  • Chemical, petrochemical and biochemical laboratories,
  • State workshops, car repair shops, printing houses,
  • Universities and schools,
  • Hospitals and clinics,
  • Filtering stations and swimming pools...

 

Considered as first aid equipments, safety showers and eye-washers must be close to risky areas. The access must be easy and well indicated.

 

REGULATION

Working Regulations:

According to R.4224-14 article, working areas must be fitted out with first aid equipment adapted to the possible risks and with an easy access. Please, refer to the local regulations in your country.
 

ISO 3864:

Labelling regulation : At the European level, it corresponds to 92/58/CEE instruction. All our first aid equipments are provided with labels in conformity with these standards.
 

European Regulation EN 15154-1:

This regulation concerns body showers, connected to water network. The main requirements are:
  • The water distribution of the emergency body shower shall be measured by this procedures : At a distance of 700mm below the shower head, 50% (± 10%) of the volume of water delivered shall fall in a circle with a diameter of 400mm, and the area reached by minimum 95% of the water shall be limited to a circle with a diameter of 800mm.
  • When no national or local regulations apply, a constant flow rate of minimum 60l/min is suitable.
  • The body shower shall be capable of delivering this supply for a minimum of 15 minutes.
  • The velocity of the water spray shall be low enough to be non-injurious to the user.
  • The shower head shall be designed to be installed so that its lower edge is 2200 (± 100) mm above the level on which the user stands.
  • The water valve shall not close automatically.
  • The manufacturer shall supply information on installation, operation and maintenance as well as the method and frequency of routing testing.
  • Showers must be provided with the appropriate label (please read above).
 

European Standard En 15154-2:

This regulation concerns eye-washers, connected to water network. The main requirements are:

  • Plumbed-in eye-wash units shall be able to deliver a constant flow rate of minimum 6l/min,
  • Eye-wash units shall be capable of delivering this supply for a minimum of 15 minutes,
  • The velocity of the water shall be low enough to be non-injurous to the user,
  • The jet of water supplied by the nozzles shall spray at a minimum height of 100mm and may spray at a maximum height of 300mm,
  • The outlet nozzles shall be installed at a height of 1000 (± 200)mm above the level on which the user stands,
  • The water valve shall not close automatically,
  • The manufacturer shall supply information on installation, operation and maintenance as well as the method and frequency of routing testing,
  • Eye-washers must be provided with the appropriate label (please read above).
 

Water Temperature:

EN 15154-1 and EN 15154-2 regulations recommend to use a water between 15°C and 37°C, in order not to worsen lesions of injuried persons and to ensure a better comfort. We advise you to use a thermostatic mixing valve (option as follow).
 
CHOOSE THE ADAPED SOLUTION TO THE INCURED RISKS
 

Risks

First-aid solutions

Projection on body

Stationary

Safety shower connected to water network

Itinerant

Portable shower stations

Eyes and face projection

Stationary

Eye-washers connected to water network

Itinerant

Autonomous eye-washers

Projection on body, eyes and face combined

Stationary

Safety combination units

Itinerant

Portable shower stations and Autonomous eye-washers

 

INSTALLATION

It is recommended to install first aid equipments close to the dangerous areas. They must be easy to access (less than 10 seconds or 30 m) and free from walls or obstructions.

 

They must be clearly identified by the staff that would use the materials.The staff must be trained to use these products. Finally, the material linked to a water network must be checked at least once a month.

 

OPTIONS

Thermostatic mixing valve (MCL-MTD)
For eye-washers: MCL For safety showers and combination units: MTD
 
Thermostatic mixing valve (MCL-MTD)
In order to avoid the risk, we recommend you to use an heating cable that prevent the risk of frozen water in the tubing untill -1°C. This solution can be used on every safety showers and eye-washers model Included: 1 m of heating cable, electrical furniture kit, and anti-freezing box.
 
       
Laboratory Chemicals
pH Indicators and Solutions
Redox Indicators
Biological Stains (Microscopy)
High Purity Solvents
High Purity Acids
Karl Fischer Reagent
Green Solvents
Bulk Packs
Honeywell Products
Concentrated Volumetric Solutions
Ion Pairing Reagents
Cavallo srl
Buffer Tablets
New Products
Ecosafe
Standard Solutions
Macherey - Nagel pH Indicators
Globally Harmonized System of classification and labelling of chemicals (GHS)

 

Disclaimer: Loba Chemie Pvt. Ltd. makes every effort to ensure that the information displayed on this web site is accurate and complete, however it is not liable for any errors, inaccuracies or omissions. Majority of the information on lobachemie.com is liable to change without any intimation or notice.

  © Copyright. LobaChemie Pvt. Ltd. All rights reserved. Home  I  Contact Us  I  Careers  I  Notices  I  Site Map